SAKYSTEEL supplies 316L electropolished stainless steel tubing for clean-fluid systems that require an EP internal surface. Electropolishing removes a controlled layer of metal to improve the microscopic surface condition. It is selected for projects that place particular importance on the wetted surface, including specified high-purity gas and liquid systems. The tube is defined by its material, EP surface acceptance, cleaning and protected delivery condition.
Material: 316L / UNS S31603
Product-contact surface: Electropolished internal surface; any external finish specified separately
Common sizes: 1/4–1 in. OD in the combinations below; metric examples also listed
Surface acceptance: Required maximum Ra, measurement basis and additional surface criteria stated in the order
Clean delivery: Post-treatment cleaning, drying, end protection and packaging matched to the project specification
The common OD and wall combinations below provide a starting point for quotation. BA and EP tubing may use the same dimensions; their distinction is the surface treatment and acceptance requirements, rather than a different OD series.
| Tube OD (in.) | Tube OD (mm) | Wall (in.) | Wall (mm) |
|---|---|---|---|
| 1/4 | 6.35 | 0.035 | 0.89 |
| 3/8 | 9.53 | 0.035 | 0.89 |
| 1/2 | 12.70 | 0.049 | 1.24 |
| 3/4 | 19.05 | 0.065 | 1.65 |
| 1 | 25.40 | 0.065 | 1.65 |
Metric size examples: 6 × 1.0, 8 × 1.0, 10 × 1.0 and 12 × 1.0 mm (OD × wall). A 6 m length or your required cut length can be quoted. Inch and metric sizes are separate ordering choices; rounded conversions are for reference. These examples do not indicate current stock or a pressure rating.
| Requirement | What it establishes |
|---|---|
| Tube material and construction | 316L / UNS S31603, seamless or welded construction, and the specified dimensional and material standard, such as ASTM A269. |
| ASTM A632, where applicable | An option only within its small-size scope: OD from 0.050 in. to under 1/2 in., and wall from 0.005 in. to under 0.065 in. It is not a blanket standard for the listed size range. |
| Electropolished surface | The required internal treatment, maximum Ra and inspection basis. Specify outside finish separately if it matters to the project. |
| SEMI F20, when required | Additional material requirements for the specified semiconductor application; EP processing alone does not demonstrate material compliance. |
| SEMI F19, when required | Wetted-surface characterization and acceptance criteria. Confirm the applicable tests and records instead of treating an Ra result as complete F19 verification. |
| Cleanliness and packaging | The required controls for particles, moisture or residues, together with cleaning, drying, handling and protective packaging. |
State whether the Ra limit is a maximum acceptance value or a process-average value, and identify the units, measurement method and sampling coverage. Results expressed in micrometres and microinches should not be confused. Inspection coverage should address the surfaces required by the project.
For critical service, roughness is only one part of acceptance. The specification may also address surface defects, surface chemistry and contamination. Identify the tests and records needed for your application so that the inspection scope can be included in the quotation.
Mechanical polishing removes material using abrasives. Electropolishing removes material electrochemically and changes the microscopic surface condition. A reflective appearance alone does not show which process was used or whether the surface meets the specification.
No. Ra describes surface roughness, not the amount of particles, moisture, oil or chemical residue present. Surface finish and cleanliness need separate acceptance criteria where the application requires them.
No. The starting material, tube manufacture, surface condition, cleaning and packaging all remain relevant. Where SEMI F20 or F19 applies, confirm the corresponding material or surface requirements and supporting records.
Selection depends on the project. EP adds a specific surface-treatment step, but final quality also depends on the starting tube and process control. Compare verified material, surface and cleanliness specifications rather than relying on the finish names alone.
Yes. EP is a treatment, while A270 is a sanitary tubing specification. A project can require both. Identify the sanitary dimensions and any BPE requirements when requesting EP tubing for hygienic processing.
Electropolishing is followed by appropriate cleaning and rinsing to remove processing residues. Drying, end protection and packing then help preserve the delivered condition. Transport, unpacking and installation must avoid recontaminating the internal surface.
Request the material and traceability documents, dimensional records and surface reports required by the project. Agree the roughness inspection scope and any additional surface or cleanliness verification before production. Specify the cleaning, drying, cap and bagging requirements. If the project requires a particular cleanroom packing class or quantitative contamination limits, include these requirements in your inquiry.
Send the OD × wall, length, quantity, construction and service medium. Include the internal Ra limit, EP and surface acceptance criteria, material standard, end preparation, cleaning and packaging requirements, and required inspection records.